Difference between revisions of "EnergyPlus"

From Wiki.OSArch
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[File:Eplus_logo_1.png]]
+
{{Infobox software
 +
| icon      = Eplus_logo_1.png
 +
| screenshot = -
 +
| website    = [https://energyplus.net/ energyplus.net]
 +
| source    = [https://github.com/NREL/EnergyPlus source]
 +
| license    = [https://energyplus.net/licensing BSD-style]
 +
| bugs      = [https://github.com/NREL/EnergyPlus/issues issues]
 +
| community  = [https://energyplus.net/support-training support & training] [https://energyplus.net/documentation documentation]
 +
| maturity  = Mature
 +
| donation  = -
 +
}}
  
EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption—for heating, cooling, ventilation, lighting and plug and process loads—and water use in buildings.
+
EnergyPlus is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption-for heating, cooling, ventilation, lighting and plug and process loads -and water use in buildings. Some of the notable features and capabilities of EnergyPlus include:
 
+
* '''Integrated, simultaneous solution''' of thermal zone conditions and HVAC system response that does not assume that the HVAC system can meet zone loads and can simulate un-conditioned and under-conditioned spaces.
Website: https://energyplus.net/
+
* '''Heat balance-based solution''' of radiant and convective effects that produce surface temperatures thermal comfort and condensation calculations.
License: [[BSD]]-Style
+
* '''Sub-hourly, user-definable time steps''' for interaction between thermal zones and the environment; with * automatically varied time steps for interactions between thermal zones and HVAC systems. These allow EnergyPlus to model systems with fast dynamics while also trading off simulation speed for precision.
 +
* '''Combined heat and mass transfer''' model that accounts for air movement between zones.
 +
* '''Advanced fenestration models''' including controllable window blinds, electrochromic glazings, and layer-by-layer heat balances that calculate solar energy absorbed by window panes.
 +
* '''Illuminance and glare calculations''' for reporting visual comfort and driving lighting controls.
 +
* '''Component-based HVAC''' that supports both standard and novel system configurations.
 +
* '''A large number of built-in HVAC and lighting control strategies''' and an extensible runtime scripting system for user-defined control.
 +
* '''Functional Mockup Interface''' import and export for co-simulation with other engines.
 +
* '''Standard summary and detailed output reports''' as well as user definable reports with selectable time-resolution from annual to sub-hourly, all with energy source multipliers.
  
 
=See also=
 
=See also=
 
* [[Ladybug Tools]]
 
* [[Ladybug Tools]]
* [[VI-Sense]]
+
* [[VI-Suite]]
 +
* [[OpenStudio]] has close bindings with EnergyPlus
 +
* [[Radiance]]
  
 
=External resources=
 
=External resources=
 +
* [https://energyplus.net/ EnergyPlus Official Website]
 +
* [https://www.sketchup.com SketchUp Official Website]
  
 
{{Template:Software}}
 
{{Template:Software}}
 
{{Template:Analysis_and_Simulation}}
 
{{Template:Analysis_and_Simulation}}
 +
[[Category:Building Energy Modeling (BEM)]]

Latest revision as of 19:27, 19 April 2025

Eplus logo 1.png
244px
Website: energyplus.net
Source: source
License: BSD-style
Bugs: issues
Community: support & training documentation
Maturity: Category:Mature
Donate: -
Red curve on white disc 128px.png Software Directory


EnergyPlus is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption-for heating, cooling, ventilation, lighting and plug and process loads -and water use in buildings. Some of the notable features and capabilities of EnergyPlus include:

  • Integrated, simultaneous solution of thermal zone conditions and HVAC system response that does not assume that the HVAC system can meet zone loads and can simulate un-conditioned and under-conditioned spaces.
  • Heat balance-based solution of radiant and convective effects that produce surface temperatures thermal comfort and condensation calculations.
  • Sub-hourly, user-definable time steps for interaction between thermal zones and the environment; with * automatically varied time steps for interactions between thermal zones and HVAC systems. These allow EnergyPlus to model systems with fast dynamics while also trading off simulation speed for precision.
  • Combined heat and mass transfer model that accounts for air movement between zones.
  • Advanced fenestration models including controllable window blinds, electrochromic glazings, and layer-by-layer heat balances that calculate solar energy absorbed by window panes.
  • Illuminance and glare calculations for reporting visual comfort and driving lighting controls.
  • Component-based HVAC that supports both standard and novel system configurations.
  • A large number of built-in HVAC and lighting control strategies and an extensible runtime scripting system for user-defined control.
  • Functional Mockup Interface import and export for co-simulation with other engines.
  • Standard summary and detailed output reports as well as user definable reports with selectable time-resolution from annual to sub-hourly, all with energy source multipliers.

See also[edit]

External resources[edit]

This page describes a software project from our AEC Free Software directory
This page is about AEC_Free_Software_directory#Analysis_and_Simulation software and the Category:Analysis_and_Simulation. This category currently includes software for Structural Analysis & Environmental Analysis.