The following [[Using MicroMVDs for exchange requirements|MicroMVD]] vocabulary can be used to ensure that data is present for basic dimensional quantity take-off.
 
The following [[Using MicroMVDs for exchange requirements|MicroMVD]] vocabulary can be used to ensure that data is present for basic dimensional quantity take-off.
  
Line 6: Line 5:
 
* Strength class: Pset_ConcreteElementGeneral.StrengthClass
 
* Strength class: Pset_ConcreteElementGeneral.StrengthClass
 
* Compressive strength: IfcMaterial.Pset_MaterialConcrete.CompressiveStrength
 
* Compressive strength: IfcMaterial.Pset_MaterialConcrete.CompressiveStrength
* Wall load bearing: Pset_WallCommon.LoadBearing – True/False
 
* Wall acousting rating: Pset_WallCommonAcousticRating – Rw / Rw + Ctr
 
* Wall fire rating: Pset_WallCommon.FireRating -/-/-
 
  
 
<pre>
 
<pre>
Line 16: Line 12:
 
For cost planners
 
For cost planners
 
All elements need to have dimensional and cost-significant metadata assigned
 
All elements need to have dimensional and cost-significant metadata assigned
 
Scenario: All walls must have cost-significant metadata
 
* All walls must have a LoadBearing property
 
* All walls must have an AcousticRating property
 
* All walls must have a FireRating property
 
  
 
Scenario: All concrete elements are identifiable and contain data
 
Scenario: All concrete elements are identifiable and contain data
Line 46: Line 37:
 
   | {value}  |
 
   | {value}  |
  
Scenario: All blockwork walls are identifiable and contain data
+
Scenario: All blockwork walls are identifiable
 
  * All blockwork walls must be assigned to a block material
 
  * All blockwork walls must be assigned to a block material
* All blockwork layers must have a thickness assigned with one of the following values:
 
  | Value |
 
  | 0.09  |
 
  | 0.19  |
 
  | 0.39  |
 
* All blockwork walls must have a core filled property assigned with one of the following values:
 
  | Value      |
 
  | None        |
 
  | 1.2m        |
 
  | Full height |
 
* All blockwork walls must have a load bearing property
 
* All blockwork walls must have a HasReinforcement property determining if they contain reinforcement
 
* All blockwork walls must have a HasStiffeners property determining if they contain stiffeners
 
  
Scenario: All brick walls are identifiable and contain data
+
Scenario: All partition walls are identifiable
* All brick walls must be assigned to a brick material
 
* All brick walls must have a finish assigned with one of the following values:
 
  | Value  |
 
  | Render |
 
  | Paint  |
 
  | None  |
 
 
 
Scenario: All partition walls are identifiable and contain data
 
 
  * All partition walls must be assigned to a partition material
 
  * All partition walls must be assigned to a partition material
* All plasterboard layers must be assigned to a plasterboard material
 
* All plasterboard materials must have an ImpactResistant property
 
* All plasterboard materials must have a MoistureResistant property
 
* All plasterboard materials must have a FireResistant property
 
  
 
Scenario: All steel elements are identifiable and contain data
 
Scenario: All steel elements are identifiable and contain data
Line 145: Line 111:
 
|}
 
|}
  
[[Category:Model View Definitions (MVD)]] [[Category:BIMTester]] [[Category:BlenderBIM Add-on]] [[Category:MicroMVD]]
+
brick wall
 +
 
 +
finish:
 +
- none
 +
- render
 +
- paint
 +
 
 +
block walls
 +
 
 +
thickness:
 +
- 90
 +
- 190
 +
- 390
 +
 
 +
core filled:
 +
- none
 +
- 1.2m
 +
- full height
 +
 
 +
load bearing:
 +
- yes
 +
- no
 +
 
 +
stiffeners (if not modeled):
 +
- yes
 +
- no
 +
 
 +
reo bars:
 +
- yes
 +
- no
 +
 
 +
partition walls
 +
 
 +
plasterboard layer:
 +
- impact resistant (yes / no)
 +
- moisure resistant (yes / no)
 +
- fire rated (yes / no)
 +
 
 +
Pset_WallCommon.LoadBearing – True/False
 +
Pset_WallCommonAcousticRating – Rw / Rw + Ctr
 +
Pset_WallCommon.FireRating -/-/-