Latest revision |
Your text |
Line 1: |
Line 1: |
− | {{Template:MVD_Documentation}}
| + | WIP: |
− | The following [[Using MicroMVDs for exchange requirements|MicroMVD]] vocabulary can be used to ensure that data is present for basic dimensional quantity take-off.
| |
| | | |
− | * Concrete material: "Concrete" in IfcMaterial.Category
| + | Walls |
− | * Concrete construction method: Pset_ConcreteElementGeneral.ConstructionMethod
| |
− | * Strength class: Pset_ConcreteElementGeneral.StrengthClass
| |
− | * Compressive strength: IfcMaterial.Pset_MaterialConcrete.CompressiveStrength
| |
− | * Wall load bearing: Pset_WallCommon.LoadBearing – True/False
| |
− | * Wall acousting rating: Pset_WallCommonAcousticRating – Rw / Rw + Ctr
| |
− | * Wall fire rating: Pset_WallCommon.FireRating -/-/-
| |
| | | |
− | <pre>
| + | * In-situ concrete: Length, Height, NetVolume, GrossSideArea |
− | Feature: Quantity take-off
| + | * Precast concrete: Length, Width, Height, GrossSideArea |
| + | * Block: Length, Width, Height, GrossSideArea |
| + | * Partition: Length, Width, Height, GrossSideArea |
| + | * Other: Length, Width, Height, GrossSideArea |
| | | |
− | In order to cost elements
| + | Slabs |
− | For cost planners
| |
− | All elements need to have dimensional and cost-significant metadata assigned
| |
| | | |
− | Scenario: All walls must have cost-significant metadata
| + | * In-situ concrete: Width, Length, Depth, Perimeter, GrossArea, GrossVolume |
− | * All walls must have a LoadBearing property
| + | * Precast concrete: Width, Length, Depth, Perimeter, GrossArea, GrossVolume |
− | * All walls must have an AcousticRating property
| + | * Other: GrossArea |
− | * All walls must have a FireRating property
| |
| | | |
− | Scenario: All concrete elements are identifiable and contain data
| + | Column |
− | * All concrete elements must be assigned to a concrete material
| |
− | * All concrete elements must have their construction method assigned with one of the following values:
| |
− | | Value |
| |
− | | In-situ |
| |
− | | Precast |
| |
− | | {value} |
| |
− | * All concrete elements must have their strength class assigned with one of the following values:
| |
− | | Value |
| |
− | | N |
| |
− | | S |
| |
− | | {value} |
| |
− | * All concrete materials must have their compressive strength assigned with one of the following values:
| |
− | | Value |
| |
− | | 20000000 |
| |
− | | 25000000 |
| |
− | | 32000000 |
| |
− | | 40000000 |
| |
− | | 50000000 |
| |
− | | 65000000 |
| |
− | | 80000000 |
| |
− | | 100000000 |
| |
− | | {value} |
| |
| | | |
− | Scenario: All blockwork walls are identifiable and contain data
| + | * Concrete: Length, OuterSurfaceArea, GrossVolume |
− | * All blockwork walls must be assigned to a block material
| + | * Steel: Length, OuterSurfaceArea, GrossVolume, GrossWeight |
− | * All blockwork layers must have a thickness assigned with one of the following values:
| + | * Other: Length, OuterSurfaceArea, GrossVolume, GrossWeight |
− | | Value |
| |
− | | 0.09 |
| |
− | | 0.19 |
| |
− | | 0.39 |
| |
− | * All blockwork walls must have a core filled property assigned with one of the following values:
| |
− | | Value |
| |
− | | None |
| |
− | | 1.2m |
| |
− | | Full height |
| |
− | * All blockwork walls must have a load bearing property
| |
− | * All blockwork walls must have a HasReinforcement property determining if they contain reinforcement
| |
− | * All blockwork walls must have a HasStiffeners property determining if they contain stiffeners
| |
| | | |
− | Scenario: All brick walls are identifiable and contain data
| + | Beam |
− | * All brick walls must be assigned to a brick material
| |
− | * All brick walls must have a finish assigned with one of the following values:
| |
− | | Value |
| |
− | | Render |
| |
− | | Paint |
| |
− | | None |
| |
| | | |
− | Scenario: All partition walls are identifiable and contain data
| + | * Concrete: Length, GrossVolume |
− | * All partition walls must be assigned to a partition material
| + | * Steel: Length, OuterSurfaceArea, GrossVolume, GrossWeight |
− | * All plasterboard layers must be assigned to a plasterboard material
| + | * Other: Length, GrossVolume |
− | * All plasterboard materials must have an ImpactResistant property
| |
− | * All plasterboard materials must have a MoistureResistant property
| |
− | * All plasterboard materials must have a FireResistant property
| |
| | | |
− | Scenario: All steel elements are identifiable and contain data
| + | Other |
− | * All steel elements must be assigned to a steel material
| |
− | * All steel elements must have a coating assigned with one of the following values:
| |
− | | Architectural |
| |
− | | Fire resistant |
| |
− | | None |
| |
− | * All steel elements must have a grade assigned with one of the following values:
| |
− | | 250 |
| |
− | | 300 |
| |
− | | 350 |
| |
− | | 400 |
| |
− | | 450 |
| |
| | | |
− | Scenario: All walls must have dimensional quantities
| + | * Footings: Length, Width, Height, GrossSurfaceArea, GrossVolume |
− | * All in-situ concrete walls must have a Length, Height, NetVolume, and GrossSideArea quantity
| + | * Railings: Length |
− | * All precast concrete walls must have a Length, Width, Height, and GrossSideArea quantity
| + | * Piles: Length, OuterSurfaceArea, GrossVolume, GrossWeight |
− | * All blockwork walls must have a Length, Width, Height, and GrossSideArea quantity
| + | * Openings: Width, Height, Depth, Area, Volume |
− | * All partition walls must have a Length, Width, Height, and GrossSideArea quantity
| + | * Stair flights: Length, GrossVolume |
− | * All other walls must have a Length, Width, Height, and GrossSideArea quantity
| + | * Structural members: Length, OuterSurfaceArea, GrossVolume, GrossWeight |
| + | * Reinforcement bar: Length, Weight |
| + | * Reinforcement mesh: Length, Width, Weight |
| + | * Curtain wall panels: GrossArea |
| + | * Window: Area |
| + | * Duct segments: Length, OuterSurfaceArea, GrossWeight |
| + | * Pipe segments: Length, OuterSurfaceArea, GrossWeight |
| | | |
− | Scenario: All slabs must have dimensional quantities
| + | Steel |
− | * All in-situ concrete slabs must have a Width, Length, Depth, Perimeter, GrossArea, and GrossVolume quantity
| |
− | * All precast concrete slabs must have a Width, Length, Depth, Perimeter, GrossArea, and GrossVolume quantity
| |
− | * All other slabs must have a GrossArea quantity
| |
| | | |
− | Scenario: All columns must have dimensional quantities
| + | painting type: |
− | * All concrete columns must have a Length, OuterSurfaceArea, and GrossVolume quantity
| + | - none |
− | * All steel columns must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
| + | - architectural paint |
− | * All other columns must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
| + | - fire resistant painting |
| | | |
− | Scenario: All beams must have dimensional quantities
| + | grade |
− | * All concrete beams must have a Length and GrossVolume quantity
| + | - 250 |
− | * All steel beams must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
| + | - 300 |
− | * All other beams must have a Length and GrossVolume quantity
| + | - 350 |
| + | - 400 |
| + | - 450 |
| | | |
− | Scenario: All foundations must have dimensional quantities
| + | brick wall |
− | * All footings must have a Length, Width, Height, GrossSurfaceArea, and GrossVolume quantity
| |
− | * All piles must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
| |
| | | |
− | Scenario: All other elements must have dimensional quantities
| + | finish: |
− | * All railings must have a Length quantity
| + | - none |
− | * All openings must have a Width, Height, Depth, Area, and Volume quantity
| + | - render |
− | * All stair flights must have a Length and GrossVolume quantity
| + | - paint |
− | * All structural members must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
| |
− | * All reinforcement bars must have a Length and Weight quantity
| |
− | * All reinforcement mesh must have a Length, Width, and Weight quantity
| |
− | * All curtain wall panels must have a GrossArea quantity
| |
− | * All windows must have an Area quantity
| |
− | * All duct segments must have a Length, OuterSurfaceArea, and GrossWeight quantity
| |
− | * All pipe segments must have a Length, OuterSurfaceArea, and GrossWeight quantity
| |
− | </pre>
| |
| | | |
− | You can fill out the variables using the guide below.
| + | block walls |
| | | |
− | {| class="wikitable"
| + | thickness: |
− | ! Variable
| + | - 90 |
− | ! Example
| + | - 190 |
− | ! Description
| + | - 390 |
− | |-
| |
− | | <code>{file}</code>
| |
− | | project.ifc
| |
− | | The filename or path to any IFC file.
| |
− | |-
| |
− | | <code>{schema}</code>
| |
− | | IFC4
| |
− | | The schema version. At the moment, these are likely to be either IFC4 or IFC2X3.
| |
− | |}
| |
| | | |
− | [[Category:Model View Definitions (MVD)]] [[Category:BIMTester]] [[Category:BlenderBIM Add-on]] [[Category:MicroMVD]]
| + | core filled: |
| + | - none |
| + | - 1.2m |
| + | - full height |
| + | |
| + | load bearing: |
| + | - yes |
| + | - no |
| + | |
| + | stiffeners (if not modeled): |
| + | - yes |
| + | - no |
| + | |
| + | reo bars: |
| + | - yes |
| + | - no |
| + | |
| + | partition walls |
| + | |
| + | plasterboard layer: |
| + | - impact resistant (yes / no) |
| + | - moisure resistant (yes / no) |
| + | - fire rated (yes / no) |
| + | |
| + | Pset_WallCommon.LoadBearing – True/False |
| + | Pset_WallCommonAcousticRating – Rw / Rw + Ctr |