The following [[Using MicroMVDs for exchange requirements|MicroMVD]] vocabulary can be used to ensure that data is present for basic dimensional quantity take-off.
 
  
* Concrete material: "Concrete" in IfcMaterial.Category
+
Walls
* Concrete construction method: Pset_ConcreteElementGeneral.ConstructionMethod
 
* Strength class: Pset_ConcreteElementGeneral.StrengthClass
 
* Compressive strength: IfcMaterial.Pset_MaterialConcrete.CompressiveStrength
 
* Wall load bearing: Pset_WallCommon.LoadBearing – True/False
 
* Wall acousting rating: Pset_WallCommonAcousticRating – Rw / Rw + Ctr
 
* Wall fire rating: Pset_WallCommon.FireRating -/-/-
 
  
<pre>
+
In-situ concrete: Length, Height, NetVolume, GrossSideArea
Feature: Quantity take-off
+
Precast concrete: Length, Width, Height, GrossSideArea
 +
Block: Length, Width, Height, GrossSideArea
 +
Partition: Length, Width, Height, GrossSideArea
 +
Other: Length, Width, Height, GrossSideArea
  
In order to cost elements
+
Slabs
For cost planners
 
All elements need to have dimensional and cost-significant metadata assigned
 
  
Scenario: All walls must have cost-significant metadata
+
In-situ concrete: Width, Length, Depth, Perimeter, GrossArea, GrossVolume
* All walls must have a LoadBearing property
+
Precast concrete: Width, Length, Depth, Perimeter, GrossArea, GrossVolume
* All walls must have an AcousticRating property
+
Other: GrossArea
* All walls must have a FireRating property
 
  
Scenario: All concrete elements are identifiable and contain data
+
Column
* All concrete elements must be assigned to a concrete material
 
* All concrete elements must have their construction method assigned with one of the following values:
 
  | Value  |
 
  | In-situ |
 
  | Precast |
 
  | {value} |
 
* All concrete elements must have their strength class assigned with one of the following values:
 
  | Value  |
 
  | N      |
 
  | S      |
 
  | {value} |
 
* All concrete materials must have their compressive strength assigned with one of the following values:
 
  | Value    |
 
  | 20000000  |
 
  | 25000000  |
 
  | 32000000  |
 
  | 40000000  |
 
  | 50000000  |
 
  | 65000000  |
 
  | 80000000  |
 
  | 100000000 |
 
  | {value}  |
 
  
Scenario: All blockwork walls are identifiable and contain data
+
Concrete: Length, OuterSurfaceArea, GrossVolume
* All blockwork walls must be assigned to a block material
+
Steel: Length, OuterSurfaceArea, GrossVolume, GrossWeight
* All blockwork layers must have a thickness assigned with one of the following values:
+
Other: Length, OuterSurfaceArea, GrossVolume, GrossWeight
  | Value |
 
  | 0.09  |
 
  | 0.19  |
 
  | 0.39  |
 
* All blockwork walls must have a core filled property assigned with one of the following values:
 
  | Value      |
 
  | None        |
 
  | 1.2m        |
 
  | Full height |
 
* All blockwork walls must have a load bearing property
 
* All blockwork walls must have a HasReinforcement property determining if they contain reinforcement
 
* All blockwork walls must have a HasStiffeners property determining if they contain stiffeners
 
  
Scenario: All brick walls are identifiable and contain data
+
Beam
* All brick walls must be assigned to a brick material
 
* All brick walls must have a finish assigned with one of the following values:
 
  | Value  |
 
  | Render |
 
  | Paint  |
 
  | None  |
 
  
Scenario: All partition walls are identifiable and contain data
+
Concrete: Length, GrossVolume
* All partition walls must be assigned to a partition material
+
Steel: Length, OuterSurfaceArea, GrossVolume, GrossWeight
* All plasterboard layers must be assigned to a plasterboard material
+
Other: Length, GrossVolume
* All plasterboard materials must have an ImpactResistant property
 
* All plasterboard materials must have a MoistureResistant property
 
* All plasterboard materials must have a FireResistant property
 
  
Scenario: All steel elements are identifiable and contain data
+
Footings: Length, Width, Height, GrossSurfaceArea, GrossVolume
* All steel elements must be assigned to a steel material
 
* All steel elements must have a coating assigned with one of the following values:
 
  | Architectural  |
 
  | Fire resistant |
 
  | None          |
 
* All steel elements must have a grade assigned with one of the following values:
 
  | 250 |
 
  | 300 |
 
  | 350 |
 
  | 400 |
 
  | 450 |
 
  
Scenario: All walls must have dimensional quantities
+
Railings: Length
* All in-situ concrete walls must have a Length, Height, NetVolume, and GrossSideArea quantity
 
* All precast concrete walls must have a Length, Width, Height, and GrossSideArea quantity
 
* All blockwork walls must have a Length, Width, Height, and GrossSideArea quantity
 
* All partition walls must have a Length, Width, Height, and GrossSideArea quantity
 
* All other walls must have a Length, Width, Height, and GrossSideArea quantity
 
  
Scenario: All slabs must have dimensional quantities
+
Piles: Length, OuterSurfaceArea, GrossVolume, GrossWeight
* All in-situ concrete slabs must have a Width, Length, Depth, Perimeter, GrossArea, and GrossVolume quantity
 
* All precast concrete slabs must have a Width, Length, Depth, Perimeter, GrossArea, and GrossVolume quantity
 
* All other slabs must have a GrossArea quantity
 
  
Scenario: All columns must have dimensional quantities
+
Openings:: Width, Height, Depth, Area, Volume
* All concrete columns must have a Length, OuterSurfaceArea, and GrossVolume quantity
 
* All steel columns must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
 
* All other columns must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
 
  
Scenario: All beams must have dimensional quantities
+
Stair flights: Length, GrossVolume
* All concrete beams must have a Length and GrossVolume quantity
 
* All steel beams must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
 
* All other beams must have a Length and GrossVolume quantity
 
  
Scenario: All foundations must have dimensional quantities
+
Structural members: Length, OuterSurfaceArea, GrossVolume, GrossWeight
* All footings must have a Length, Width, Height, GrossSurfaceArea, and GrossVolume quantity
 
* All piles must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
 
  
Scenario: All other elements must have dimensional quantities
+
Reinforcement bar: Length, Weight
* All railings must have a Length quantity
 
* All openings must have a Width, Height, Depth, Area, and Volume quantity
 
* All stair flights must have a Length and GrossVolume quantity
 
* All structural members must have a Length, OuterSurfaceArea, GrossVolume, and GrossWeight quantity
 
* All reinforcement bars must have a Length and Weight quantity
 
* All reinforcement mesh must have a Length, Width, and Weight quantity
 
* All curtain wall panels must have a GrossArea quantity
 
* All windows must have an Area quantity
 
* All duct segments must have a Length, OuterSurfaceArea, and GrossWeight quantity
 
* All pipe segments must have a Length, OuterSurfaceArea, and GrossWeight quantity
 
</pre>
 
  
You can fill out the variables using the guide below.
+
Reinforcement mesh: Length, Width, Weight
  
{| class="wikitable"
+
Curtain wall panels:: GrossArea
! Variable
 
! Example
 
! Description
 
|-
 
| <code>{file}</code>
 
| project.ifc
 
| The filename or path to any IFC file.
 
|-
 
| <code>{schema}</code>
 
| IFC4
 
| The schema version. At the moment, these are likely to be either IFC4 or IFC2X3.
 
|}
 
  
[[Category:Model View Definitions (MVD)]] [[Category:BIMTester]] [[Category:BlenderBIM Add-on]] [[Category:MicroMVD]]
+
Window: Area
 +
 
 +
Duct segments: Length, OuterSurfaceArea, GrossWeight
 +
 
 +
Pipe segments: Length, OuterSurfaceArea, GrossWeight