Difference between revisions of "MicroMVDs for exchange requirements/Construction sequencing MicroMVD"

From Wiki.OSArch
(Created page with "The following MicroMVD vocabulary can be used for construction sequencing data. <pre> Feature: Construction sequencing In order...")
 
Line 14: Line 14:
 
   | BORED  |
 
   | BORED  |
 
   | DRIVEN |
 
   | DRIVEN |
 +
 +
Scenario: All multistorey elements are divided per storey
 +
* All walls are limited to the height of their current storey.
 +
* All columns are limited to the height of their current storey.
 
</pre>
 
</pre>
  

Revision as of 22:23, 11 October 2021

The following MicroMVD vocabulary can be used for construction sequencing data.

Feature: Construction sequencing

In order to analyse construction sequencing schedules
For construction sequencers and site managers
Specific model metadata and structure is required

Scenario: All piles are identifiable and contain data
 * All piles must be assigned to a concrete or steel material
 * All piles must have their type assigned with one of the following values:
   | Value  |
   | BORED  |
   | DRIVEN |

Scenario: All multistorey elements are divided per storey
 * All walls are limited to the height of their current storey.
 * All columns are limited to the height of their current storey.

You can fill out the variables using the guide below.

Variable Example Description
{guid} 28q3AgmxP5cepIweO5Of$o This is a 22 character GlobalId for a particular IFC element.